Page 123 - OP_Katalog_EN
P. 123

GAS
                                                                                                           GAS
               OPP-SOR® Gas measuring sensors



               Housing versions    Selection table for gas sensors from page 126 on

                                   OPP-SOR® GMF 4 type gas sensor
                                   in aluminum housing;
                                   color: gray; dimensions: 125 x 80 x 60 mm (W x H x D); protection type: IP 44
                                   available, e.g., for carbon monoxide, nitrogen dioxide (diesel smoke), oxygen, propane (LPG), natural gas /
                                   methane and refrigerants.
                                   Data sheet no. 38100 / 38101 / 38102 / 38103 / 38105 / 38112 / 38113

                                   OPP-SOR® GMF 5 type gas sensor
                                   in plastic housing
                                   color: gray; dimensions: 130 x 95 x 60 mm (W x H x D); protection type: IP 44
                                   available, e.g., for carbon monoxide, nitrogen dioxide (diesel smoke), propane (LPG), natural gas /
                                   methane and refrigerants.
                                   Data sheet no. 38106 / 38107

                                   OPP-SOR® GMF 4.IR
                                   type infrared gas sensor
                                   in aluminum housing;
                                   Circuit board includes 2 output relays for horn and warning sign or 1 output relay for warning
                                   sign in type HP-MOD (HP = integrated horn).
                                   measurement principle: infrared technology using state-of-the-art dual beam technique;
                                   corrected for contamination, air pressure, temperature and humidity and extremely accurate;
                                   minimum cross-sensitivity, hence no on-site recalibration required but instead only a trigger test
                                   using calibration gas;
                                   especially well-suited for critical monitoring tasks such as in cold storages
                                   color: gray; dimensions: 125 x 80 x 60 mm (W x H x D); protection type: IP 54;
                                   available, e.g., for carbon monoxide, natural gas / methane and refrigerants.
                                   Data sheet no. 38109 / 38111

                                   OPP-SOR® GMF 5.IR                                                                  GAS WARNING DEVICES
                                   type infrared gas sensor
                                   in plastic housing;
                                   Circuit board includes 2 output relays for horn and warning sign.
                                   measurement principle: infrared technology using state-of-the-art dual beam technique;
                                   corrected for contamination, air pressure, temperature and humidity and extremely accurate;
                                   minimum cross-sensitivity, hence no on-site recalibration required but instead only a trigger test
                                   using calibration gas;
                                   especially well-suited for critical monitoring tasks such as in cold storages
                                   color: gray; dimensions: 130 x 95 x 60 mm (W x H x D); protection type: IP 54;
                                   available, e.g., for carbon monoxide, natural gas / methane and refrigerants.
                                   Data sheet no. 38110

                                   OPP-SOR® GMF 4DUO type gas sensor
                                   in two separate aluminum housings for optimal positioning; color: gray;
                                   dimensions: 125 x 80 x 60 mm (W x H x D); protection type: IP 44; combination: CO + LPG
                                   measurement principle for CO: electrochemical, corrected for temperature and humidity;
                                   measurement principle for LPG: pellistor; logarithmic signal curve;
                                   gas entry via sintered filter; also available for CO + NO2.
                                   Data sheet no. 38104

                                   OPP-SOR® GMF type combined sensor 5.E.CO+NO2.08+03.MOD
                                   in plastic housing;
                                   color: gray; dimensions: 130 x 95 x 60 mm (W x H x D); protection type: IP 44;
                                   measurement principle: electrochemical; corrected for temperature and humidity, hence high accuracy and low
                                   cross-sensitivity to other gases.
                                   Data sheet no. 38108



               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Gas warning devices  |  123
   118   119   120   121   122   123   124   125   126   127   128