Page 108 - OP_Katalog_EN
P. 108

OPP-ROOM® I / O module
                                                                      Type              Item no. ADG Euro  /  pc.

                       OPP-ROOM® I / O module                                                      see our
                       For connecting external analog portable devices and room                    current
                       sensors, conversion to Modbus or BACnet.                                    price list
                       Display not possible.

                       Supply voltage:     24 V AC / DC
                       Permiss. amb. cond.:     -30 – 70 °C, 0 – 95 % RH
                                           (non-condensing)
                       Housing:            Plastic (ABS); IP20,
                                             White similar to RAL 9010,
                                           wall-mounted
                       Dimensions:         86 x 120 x 25 mm (L x W x D)
                       Terminals:          Screw terminals 0.05 – 1.5 mm2

                       Version IO4:
                       Inputs:             2 x switching input
                                           (closer, potential-free)
                       Outputs:            2 x DO digital outputs –
                                           only with 24 V AC supply voltage

                       Modbus transmitter (Modbus RTU)                IO-MOD-R-IO4       103916  23

                       BACnet transmitter (MS / TP)                   IO-BAC-R-IO4       103914  23

                       Version IO9:
                       Inputs:             2 x switching input
                                           (closer, potential-free)
                                           2 x analog input
                                           (0 – 50 kΩ, e.g. for NTC)
                       Outputs:            3 x 0 – 10 V DC
                                           2 x DO digital outputs –
                                           only with 24 V AC supply voltage

                       Modbus transmitter (Modbus RTU)                IO-MOD-R-IO9       103915  23

                       BACnet transmitter (MS / TP)                   IO-BAC-R-IO9       103913  23
                       Data sheet no. 20550
                       BACnet protocol OPP-ROOM
                       (downloadable from our website)

                       OPP-ROOM® USB configuration cable              CAB-02             103918  23
                       For connecting active OPP-ROOM® transmitters with the PC.
                       Needed to configure the transmitter with OR-C software.
























          108  |  Catalog 2024  |  Sensors   For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1
   103   104   105   106   107   108   109   110   111   112   113