Page 103 - OP_Katalog_EN
P. 103

OPP-ROOM® Room temperature sensors

               optionally with occupancy + LUX brightness sensor
                                                                            Type              Item no. ADG Euro  /  pc.

                             OPP-ROOM® Room temperature sensor (active)                                  see our
                             For measuring interior air temperature.                                     current
                             Optionally with occupancy + LUX brightness sensor.                         price list
                             Also available with LCD display
                             Color change (alarm function):
                             Backlighting changes its color when a pre-programmed alarm
                             threshold is reached (white - yellow - red), adjustable brightness.

                             The OR-C configuration software must be used to assign sensor                            SENSORS
                             metrics to outputs, to program simple control parameters, the
                             display, for wall calibration, and any expanded bus settings.

                             Supply voltage:     24 V AC / DC
                             Measurement range:   0 – 50 °C,
                                                 0 – 3,000 LUX (option PIR-LUX)
                             Permiss.
                             ambient conditions:     -30 – 70 °C, 0 – 95 % RH
                                                 (non-condensing)
                             Housing:            Plastic (ABS); IP20,
                                                   White similar to RAL 9010,
                                                 wall-mounted
                             Dimensions:         86 x 120 x 25 mm (L x W x D)
                             Terminals:          Screw terminals 0.05 – 1.5 mm2

                             Voltage transmitter 3-wire, Output 0 – 10 V
                             without display                                T-TV-R            103868  23
                             with display                                   T-TV-R-D          103872  23
                             Modbus transmitter (Modbus RTU)
                             without display                                T-MOD-R           103894  23
                             with display                                   T-MOD-R-D         103898  23
                             BACnet transmitter (MS / TP)
                             without display                                T-BAC-R           103902  23
                             with display                                   T-BAC-R-D         103906  23

                             Options:
                             Button (illuminated)                           xxx-BL             s. table
                             Setpoint potentiometer active (only Modbus and BACnet)  xxx-P1    s. table
                             Setpoint potentiometer passive (10 kΩ, on current / voltage output)  xxx-P2  s. table
                             Occupancy + LUX brightness sensor              xxx-PIR-LUX        s. table

                             Data sheet no. 20521
                             BACnet protocol OPP-ROOM
                             (downloadable from our website)

                             OPP-ROOM® USB configuration cable              CAB-02            103918  23
                             For connecting active OPP-ROOM® transmitters with the PC.
                             Needed to configure the transmitter with OR-C software.


















               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Sensors  |  103