OPP-ROOM® Room temperature controller
                                                                            Type              Item no. ADG Euro  /  pc.

                             OPP-ROOM® Room temperature controller                                       see our
                             To control room temperature (heating and cooling).                          current
                             Including setpoint potentiometer (active) to adjust the desired            price list
                             room temperature.
                             Also available with LCD display
                             The OR-C configuration software must be used to assign sensor
                             metrics to outputs, to program simple control parameters, the
                             display, for wall calibration, and any expanded bus settings.
                                                                                                                      SENSORS
                             Supply voltage:     24 V AC / DC
                             Measurement range:   0 – 50 °C
                             Permiss. amb. cond.:     -30 – 70 °C, 0 – 95 % RH
                                                 (non-condensing)
                             Housing:            Plastic (ABS); IP20,
                                                   White similar to RAL 9010,
                                                 wall-mounted
                             Dimensions:         86 x 120 x 25 mm (L x W x D)
                             Terminals:          Screw terminals 0.05 – 1.5 mm2
                             Dead zone:          0 – 3 °C
                             P band:             1 – 25 °C
                             Setpoint
                             potentiometer:      Adjustable range 18 – 24 °C
                                                 Configurable center point

                             Inputs:             1 switching input (closer, potential-free)
                                                 1 NTC10 external (auto detect)

                             Outputs:            3 x 0 – 10 V DC (1x heating,
                                                   2 x cooling) configurable with” coil
                                                 changeover” function
                                                 2 x DO (digital output –
                                                 only with 24 AC power supply)
                                                 Configurable on 3 way or PWM.

                             Analog version with output 0 – 10 V DC
                             without display, with two LEDs (heating / cooling)  C1-TV-R-P1L  103919  23
                             with display, without separate LEDs            C1-TV-R-D-P1      103920  23
                             Modbus version (Modbus RTU)
                             without display, with two LEDs (heating / cooling)  C1-MOD-R-P1L  103921  23
                             with display, without separate LEDs            C1-MOD-R-D-P1     103922  23
                             BACnet version (MS / TP)
                             without display, with two LEDs (heating / cooling)   C1-BAC-R-P1L  103923  23
                             with display, without separate LEDs            C1-BAC-R-D-P1     103924  23
                             Data sheet no. 20530
                             BACnet protocol OPP-ROOM
                             (downloadable from our website)

                             OPP-ROOM® USB configuration cable              CAB-02            103918  23