Page 94 - OP_Katalog_EN
P. 94

Accessories for STB / TW
                                                                      Type              Item no. ADG Euro  /  pc.

                       Wall mounting bracket                          WBB                104234  02  see our
                       for raised mounting                                                         current
                       The wall mounting bracket is used for mounting the tempera-                 price list
                       ture limiter STB or temperature monitor TW at a distance from
                       the measuring point. The bracket is required in cases where the
                       capillary tube cannot be laid through the recess in the housing
                       bottom and clearance is required between the STB or TW and the
                       mounting surface.
                       Data sheet no. 20680

                       Spacer 50 mm                                   DS-50              104235  02
                       The spacer can be used for mounting across insulation material.
                       Data sheet no. 20680

                       Spacer 100 mm                                  DS-100             104236  02
                       The spacer can be used for mounting across insulation material.
                       Data sheet no. 20680






                       Installation examples

                       Mounting on the immersion sleeve
                       The STB / TW can be mounted on the immersion sleeve TH.
                       The housing bottom has a recess matching the size of the immersion sleeve TH.

                       Recommended accessories*: immersion sleeve TH

                       On-wall mounting
                       The STB / TW can be mounted directly on a wall.
                       In this case the capillary tube must be laid through the recess in the housing bottom.

                       Recommended accessories*: immersion sleeve TH, holding bracket HK

                       On-wall mounting with bracket
                       The wall mounting bracket can be used to mount the STB / TW so that it is raised from the mounting surface.
                       The capillary does then not need to be laid through the recess in the housing bottom.


                       Recommended accessories*: wall mounting bracket WBB, holding bracket HK

                       On-pipe mounting
                       The tension band SB-02 is used for mounting the SBT / TW on a pipe.
                       The capillary tube then functions as a contact sensor.
                       Suitable for pipe diameters from 0.5" to 3".

                       Recommended accessories*: tension band SB-02

                       In-air-duct mounting
                       Using the helical holder the capillary sensor can also be mounted in the air duct.

                       Recommended accessories*: helical holder SWH, holding bracket HK

                       *  This list is not necessarily complete.
                        What accessories are required also depends on the requirements of the application and the conditions on site.




          94  |  Catalog 2024  |  Sensors   For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1