Airflow sensors
                                                                            Type              Item no. ADG Euro  /  pc.

                             Air flow monitor 230 V AC                      SL 101.1          101603  01  see our
                             Air flow monitor 24 V AC                       SL 101.2          101604  01  current
                             Air flow monitor 24 V DC                       SL 101.3          101605  01  price list
                             with mounting flange for installation in ventilation ducts. Optical
                             indicator of the operating conditions (start-up – operation – failure)
                             via LED. Calorimetric measuring principle. 1 floating normally open
                             contact. The threshold value can be set infinitely by a potentiometer.
                             Setting range: 1 – 10 m / s.
                             If the threshold value is undershot, the relay drops out.                                SENSORS
                             Maximum immersion depth:   115 mm
                             Permiss. amb. cond.:       -10 – 50 °C, 0 – 90 % RH
                                                      (non-condensing)
                             Protection class:        IP 65
                             Breaking capacity of the relay contact: 3 A / 250 V
                             Terminal cable:          2 m, 4 x 0.5 mm2
                             Data sheet no. 11101

                             Air flow monitor 230 V AC                      RLSW 6.1.1        101453  01
                             Air flow monitor 24 V AC / DC                  RLSW 6.1.5        101454  01
                             Compact device for on-site mounting with a separate
                             airflow sensor and mounting flange for duct installation
                             Calorimetric measuring principle. With compensation of
                             temperature and sensor rupture protection. 2 floating
                             switching contacts. Internal reset push-button.
                             The following parameters can be set via potentiometer:
                             Flow speed:              0.2 – 15 m / s
                             Switching hysteresis:    1 – 10 %
                             Start-up bridging:       15 – 120 s
                             Switch-off delay:        2 – 20 s
                             The air flow monitor is activated on applying the voltage. If the set
                             flow speed is reached during the startup lag, the flow monitoring
                             relay connects and e.g. enables humidification. If the flow speed is
                             not reached, the alarm relay connects. If the flow speed falls below
                             the set value during operation, the flow relay connects after a
                             switch-off delay.
                             Maximum immersion depth of the sensor:  120 mm
                             Protection class sensor:   IP 67
                             Protection class housing:   IP 65
                             Media temperature:       -10 – 80 °C
                             Permiss. amb. cond.:       0 – 60 °C, 0 – 95 % RH
                                                      (non-condensing)
                             Protection class:        IP 54
                             Breaking capacity of the relay contacts: 10 A / 250 V
                             Terminal cable of sensor:    1.8 m, 3 x 0.5 mm2
                             Data sheet no. 11201

                             Air flow transducer 24 V DC                    SL 520 1.3S       105583  01
                             with mounting flange for installation in ventilation ducts. Visual indica-
                             tion of operating status through LED.Calorimetric measuring principle.
                             1 analog output 0 – 10 V (not linear – please see data sheet).
                             Setting range:           2 m / s = 1 V – 20 m / s = 10 V
                             Maximum immersion depth:   115 mm
                             Permiss. amb. cond.:       -10 – 50 °C, 0 – 90 % RH
                                                      (non-condensing)
                             Protection class:        IP 65
                             Terminal cable:          2 m, 4 x 0.5 mm2, plug M16
                             Data sheet no. 11102



               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Sensors  |  77