Page 72 - OP_Katalog_EN
P. 72

Senso

          Volume flow indicator & transmitter
                                                                      Type              Item no. ADG Euro  /  pc.

                       Low-pressure flow indicator-transmitter-monitor Senso VP                    see our
                       Highly accurate – especially for volume flow                                current
                       measurements with pitot tubes (e. g. Prandtl).                              price list
                       Round built-in type unit with large LCD display.
                       k value and r (Rho) programmable.
                       Units of measure:   m³ / h or l / sec or ft³ / min
                       Adjustable threshold with red LED indication in case of undershoot.
                       Working range:   0 – 99,990 m³/h
                       Error margin:   ± 1 Pa (Tu 10 °C – 30 °C)
                                     ± 2 Pa (Tu < 10 °C or > 30°C)
                                     analog output ≤ 1% of
                                     measuring range
                       Measuring range:   0 – 250 Pa
                       Installation
                       dimensions:    114 x 48 mm (ø x H)
                       2 connection fittings:  ø 6 mm flush with the rear side
                       Supply voltage:    24 V AC / DC
                       Output 1:     0(2) – 10 V ≙ 0 – 99,990 m³/h
                       Output 2:     0(4) – 20 mA ≙ 0 – 99,990 m³/h
                       Output 3:     relay with floating changeover
                                     contact
                       Protection class:   IP 54, with additional O-Ring IP 64
                                     (see accessories)
                       Permiss.
                       amb. cond.      -10 – 40 °C, 0 – 75 % RH
                                     (non-condensing)
                       Senso accessories on page 58
                       Note: Please order together with the desired clima-set
                       (straight or right-angle) for the connection (see page 58).

                       Snap-fit cover for built-in type unit,
                       including Senso-ZP-type mounting set
                       square design                                  VP250-00-SET       102835  13
                       round design                                   VP250-01-SET       102836  13

                       Surface-mounted housing configuration
                       Technical specifications as above, but with protection class IP 65   VP250-AP   104163  13
                       and differing dimensions; connection fittings / electrical connection
                       pointing down; without assembly kit.
                       Data sheet no. 13159




























          72  |  Catalog 2024  |  Sensors   For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1