Page 49 - OP_Katalog_EN
P. 49

OPP-SENS® Duct enthalpy

               humidity temperature sensors
                                                                            Type              Item no. ADG Euro  /  pc.

                             Immersion length 50 – 150 mm:                                               see our
                             Current transmitter (2-wire, 4 – 20 mA)                                     current
                             without display*                               HTx-TC-I-150       103512 22  price list
                             with display and NFC interface                 HTx-TC-I-150-D-NFC  105169 22
                             Current/Voltage transmitter
                             (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                             without display*                               HTx-T-I-150        103514 22
                             with display and NFC interface                 HTx-T-I-150-D-NFC  105171 22
                             Modbus transmitter (Modbus RTU)                                                          SENSORS
                             without display*                               HTx-MOD-I-150      103516 22
                             with display and NFC interface                 HTx-MOD-I-150-D-NFC 105167 22
                             BACnet transmitter (MS / TP)
                             without display*                               HTx-BAC-I-150      103518 22
                             with display and NFC interface                 HTx-BAC-I-150-D-NFC  105165 22

                             Immersion length 200 – 400 mm:
                             Current transmitter (2-wire, 4 – 20 mA)
                             without display*                               HTx-TC-I-400       103520 22
                             with display and NFC interface                 HTx-TC-I-400-D-NFC  105170 22
                             Current/Voltage transmitter
                             (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                             without display*                               HTx-T-I-400        103522 22
                             with display and NFC interface                 HTx-T-I-400-D-NFC  105172 22
                             Modbus transmitter (Modbus RTU)
                             without display*                               HTx-MOD-I-400      103524 22
                             with display and NFC interface                 HTx-MOD-I-400-D-NFC 105168 22
                             BACnet transmitter (MS / TP)
                             without display*                               HTx-BAC-I-400      103526 22
                             with display and NFC interface                 HTx-BAC-I-400-D-NFC  105166 22
                             Data sheet no. 20912
                             BACnet protocol OPP-SENS (downloadable from our website)


                             *  For programming/assigning addresses and 5P calibration, a display must be used at least once.






































               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Sensors  |  49
   44   45   46   47   48   49   50   51   52   53   54